TLC7528C, TLC7528E, TLC7528I
DUAL 8-BIT MULTIPLYING
DIGITAL-TO-ANALOG CONVERTERS
SLAS062B – JANUARY 1987 – REVISED MARCH 2000
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VDD (to AGND or DGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 16.5 V
Voltage between AGND and DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± VDD
Input voltage range, VI (to DGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3
Reference voltage, VrefA or VrefB (to AGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 25 V
Feedback voltage VRFBA or VRFBB (to AGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 25 V
Input voltage (voltage mode out A, out B to AGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3
Output voltage, VOA or VOB (to AGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 25 V
Peak input current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 µA
Operating free-air temperature range, TA: TLC7528C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLC7528I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 25°C to 85°C
TLC7528E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Case temperature for 10 seconds, TC: FN package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: DW or N package . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
Reference voltage, VrefA or VrefB
High-level input voltage, VIH
Low-level input voltage, VIL
CS setup time, tsu(CS)
CS hold time, th(CS)
DAC select setup time, tsu(DAC)
DAC select hold time, th(DAC)
Data bus input setup time tsu(D)
Data bus input hold time th(D)
Pulse duration, WR low, tw(WR)
Operating free-air temperature, TA
TLC7628C
TLC7628I
TLC7628E
VDD = 4.75 V to 5.25 V VDD = 14.5 V to 15.5 V
MIN NOM MAX MIN NOM MAX
± 10
± 10
2.4
13.5
0.8
1.5
50
50
0
0
50
50
10
10
25
25
10
10
50
50
0
70
0
70
– 25
85 – 25
85
– 40
85 – 40
85
UNIT
V
V
V
ns
ns
ns
ns
ns
ns
ns
°C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3