English
Language : 

TLC5617 Datasheet, PDF (3/20 Pages) Texas Instruments – PROGRAMMABLE DUAL 10-BIT DIGITAL-TO-ANALOG CONVERTERS
TLC5617, TLC5617A
PROGRAMMABLE DUAL 10-BIT DIGITAL-TO-ANALOG CONVERTERS
SLAS151B – JULY 1997 – REVISED MARCH 2000
Terminal Functions
TERMINAL
NAME
NO.
AGND
5
CS
3
DIN
1
OUT A
4
OUT B
7
REFIN
6
SCLK
2
VDD
8
I/O
DESCRIPTION
Analog ground
I Chip select, active low
I Serial data input
O DAC A analog output
O DAC B analog output
I Reference voltage input
I Serial clock input
Positive power supply
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage (VDD to AGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Digital input voltage range to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3 V
Reference input voltage range to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3 V
Output voltage at OUT from external source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDD + 0.3 V
Continuous current at any terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Operating free-air temperature range, TA: TLC5617C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLC5617I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
Supply voltage, VDD
High-level digital input voltage, VIH
Low-level digital input voltage, VIL
Reference voltage, Vref to REFIN terminal
Load resistance, RL
Operating free-air temperature, TA
VDD = 5 V
VDD = 5 V
TLC5617C
TLC5617I
MIN
4.5
0.7 VDD
1
2
0
– 40
NOM
5
MAX
5.5
0.3 VDD
2.048 VDD – 1.1
70
85
UNIT
V
V
V
V
kΩ
°C
°C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265