English
Language : 

TL441CN Datasheet, PDF (3/20 Pages) Texas Instruments – LOGARITHMIC AMPLIFIER
TL441
LOGARITHMIC AMPLIFIER
SLVS328 – OCTOBER 2000
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltages (see Note 1): VCC+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 V
VCC – . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 8 V
Input voltage (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V
Output sink current (any one output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
Package thermal impedance, θJA (see Notes 2 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltages, except differential out voltages, are with respect to network ground terminal.
2. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
Peak-to-peak input voltage for each 30-dB stage
Operating free-air temperature, TA
electrical characteristics, VCC± = ±6 V, TA = 25°C
PARAMETER
Differential output offset voltage
Quiescent output voltage
DC scale factor (differential output), each 3-dB stage, – 35 dBV to – 5 dBV
AC scale factor (differential output)
DC error at – 20 dBV (midpoint of – 35 dBV to – 5 dBV range)
Input impedance
Output impedance
Rise time, 10% to 90% points, CL = 24 pF
Supply current from VCC+
Supply current from VCC –
Power dissipation
MIN MAX UNIT
0.01
1V
0
70 °C
TEST
FIGURE
1
2
3
3
4
2
2
2
MIN TYP MAX UNIT
±40
mV
5.45 5.6 5.85 V
6
8
12 mV/dB
8
mV/dB
1
dB
500
Ω
200
Ω
20
30 ns
14.5 18.5
23 mA
– 6 – 8.5 – 10.5 mA
123 162
201 mW
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3