English
Language : 

TL3414A_06 Datasheet, PDF (3/9 Pages) Texas Instruments – DUAL HIGH OUTPUT CURRENT OPERATIONAL AMPLIFIER
TL3414A
DUAL HIGHĆOUTPUTĆCURRENT OPERATIONAL AMPLIFIER
recommended operating conditions
VCC
VCC +
VCC −
VID
VI
TA
Supply voltage (single supply)
Supply voltage (dual supply)
Supply voltage (dual supply)
Differential input voltage
Input voltage
Operating free-air temperature range
SLOS453A − DECEMBER 2004 − REVISED JANUARY 2005
MIN
3
1.5
−1.5
−0.3
−40
MAX
15
7.5
−7.5
15
15
85
UNIT
V
V
V
V
V
°C
DC electrical characteristics, VCC+ = 5 V, VCC− = 0 V, TA = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
VIO Input offset voltage
RS = 0 Ω
2
5 mV
IIO
Input offset current
15 100 nA
IIB
Input bias current
300 600 nA
AVD Large-signal differential voltage amplification RL = 2 kΩ
77 100
dB
VICR Common-mode input voltage range
VCC+ − 2 V
V
VOM Output voltage swing
RL > 2 kΩ, VCC+ = 5 V
IO = 70 mA, VCC+ = 5 V
3.5
V
3.2
CMRR Common-mode rejection ratio
70
79
dB
kSVR† Supply-voltage rejection ratio
80
90
dB
ICC Supply current (all amplifiers)
RL = open circuit (full temperature range)
† Measured with VCC± differentially and simultaneously varied from 5 V to 8.6 V
3
4
6 mA
AC electrical characteristics, VCC+ = 5 V, VCC− = 0 V, TA = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TYP UNIT
SR
Slew rate at unity gain
0.83 V/µs
GBW Gain bandwidth product
1.1 MHz
Vn
Equivalent input noise voltage
f = 1 kHz
18 nV/√Hz
DC electrical characteristics, VCC+ = 8.6 V, VCC− = 0 V, TA = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
VIO
IIO
IIB
AVD
Input offset voltage
Input offset current
Input bias current
Large-signal differential voltage
amplification
RS = 0 Ω
RL = 2 kΩ
2
5 mV
15 100 nA
300 600 nA
88 105
dB
VICR Common-mode input voltage range
VCC+ − 2 V
RL > 2 kΩ, VCC+ = 8.6 V
7
VOM Output voltage swing
IO = 70 mA, VCC+ = 8.6 V
6.7
CMRR Common-mode rejection ratio
80
90
kSVR† Supply-voltage rejection ratio
80
90
ICC
Supply current (all amplifiers)
RL = open circuit (full temperature range)
† Measured with VCC± differentially and simultaneously varied from 5 V to 8.6 V
3
4
V
V
dB
dB
6 mA
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3