English
Language : 

TL317 Datasheet, PDF (3/7 Pages) Texas Instruments – 3-TERMINAL ADJUSTABLE REGULATORS
TL317
3-TERMINAL ADJUSTABLE REGULATORS
SLVS004C – APRIL 1979 – REVISED JULY 1999
electrical characteristics over recommended operating virtual-junction temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS†
TL317C
UNIT
MIN TYP MAX
Input voltage regulation (see Note 3)
Ripple regulation
VI – VO = 5 V to 35 V
TJ = 25°C
IO = 2.5 mA to 100 mA
VO = 10 V,
f = 120 Hz
VO = 10 V,
10-µF capacitor between ADJUSTMENT and ground
0.01 0.02
%V
0.02 0.05
65
dB
66
80
Output voltage regulation
Output voltage change with temperature
Output voltage long-term drift
Output noise voltage
Minimum output current to maintain regulation
Peak output current
ADJUSTMENT current
VI = 5 V to 35 V,
IO = 2.5 mA to 100 mA,
TJ = 25°C
VO ≤ 5 V
VO ≥ 5 V
VI = 5 V to 35 V,
IO = 2.5 mA to 100 mA
VO ≤ 5 V
VO ≥ 5 V
TJ = 0°C to 125°C
After 1000 hours at TJ = 125°C and VI – VO = 35 V
f = 10 Hz to 10 kHz,
TJ = 25°C
VI – VO = 35 V
VI – VO ≤ 35 V
25
mV
5
mV/V
50
mV
10
mV/V
10
mV/V
3
10 mV/V
30
µV/V
1.5 2.5 mA
100 200
mA
50 100 µA
Change in ADJUSTMENT current
VI – VO = 2.5 V to 35 V, IO = 2.5 mA to 100 mA
0.2
5 µA
Reference voltage (output to ADJUSTMENT)
VI – VO = 5 V to 35 V,
P ≤ rated dissipation
IO = 2.5 mA to 100 mA,
1.2 1.25
1.3
V
† Unless otherwise noted, these specifications apply for the following test conditions: VI – VO = 5 V and IO = 40 mA. Pulse-testing techniques must
be used that maintain the junction temperature as close to the ambient temperature as possible. All characteristics are measured with a 0.1-µF
capacitor across the input and a 1-µF capacitor across the output.
NOTE 3: Input voltage regulation is expressed here as the percentage change in output voltage per 1-V change at the input.
electrical characteristics over recommended operating conditions, TJ = 25°C (unless otherwise
noted)
PARAMETER
TEST CONDITIONS†
TL317Y
UNIT
MIN TYP MAX
Input voltage regulation (see Note 3)
Ripple regulation
VI – VO = 5 V to 35 V
VO = 10 V,
f = 120 Hz
VO = 10 V,
10-µF capacitor between ADJUSTMENT and ground
0.01
%V
65
dB
80
Output voltage regulation
Output noise voltage
IO = 2.5 mA to 100 mA
f = 10 Hz to 10 kHz
VO ≤ 5 V
VO ≥ 5 V
25
mV
5
mV/V
30
µV/V
Minimum output current to maintain regulation
Peak output current
ADJUSTMENT current
VI – VO = 35 V
VI – VO ≤ 35 V
1.5
mA
200
mA
50
µA
Change in ADJUSTMENT current
VI – VO = 2.5 V to 35 V, IO = 2.5 mA to 100 mA
0.2
µA
Reference voltage (output to ADJUSTMENT)
VI – VO = 5 V to 35 V,
P ≤ rated dissipation
IO = 2.5 mA to 100 mA,
1.25
V
† Unless otherwise noted, these specifications apply for the following test conditions: VI – VO = 5 V and IO = 40 mA. Pulse-testing techniques must
be used that maintain the junction temperature as close to the ambient temperature as possible. All characteristics are measured with a 0.1-µF
capacitor across the input and a 1-µF capacitor across the output.
NOTE 3: Input voltage regulation is expressed here as the percentage change in output voltage per 1-V change at the input.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3