absolute maximum ratings over operating free-air temperature range†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 V
Amplifier input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Collector output voltage, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 V
Collector output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 mA
Continuous power total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA C suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –20°C to 85°C
Q suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 125°C
M suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
PACKAGE
D
DB
N
NS
PW
FK
J
TA ≤ 25°C
POWER RATING
1088 mW
775 mW
1000 mW
500 mW
838 mW
1375 mW
1375 mW
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25°C
8.7 mW/°C
TA = 70°C
POWER RATING
696 mW
6.2 mW/°C
496 mW
8.0 mW/°C
640 mW
4.0 mW/°C
320 mW
6.7 mW/°C
536 mW
11.0 mW/°C
880 mW
11.0 mW/°C
880 mW
TA = 85°C
POWER RATING
566 mW
403 mW
520 mW
260 mW
436 mW
715 mW
715 mW
TA = 125°C
POWER RATING
218 mW
—
—
—
168 mW
275 mW
275 mW
recommended operating conditions
Supply voltage, VCC
Amplifier input voltage, VI
Collector output voltage, VO
Collector output current, IO
Current into feedback terminal
Feedback resistor, RF
Timing capacitor, CT
Timing resistor, RT
Oscillator frequency
Operating free-air temperature, TA
C suffix
Q suffix
M suffix
MIN MAX UNIT
3.6
50 V
1.05 1.45 V
50 V
20 mA
45 µA
100
kΩ
150 15000 pF
5.1
100 kΩ
1
500 kHz
–20
85
–40
125 °C
–55
125
www.ti.com
3