English
Language : 

SN74CBTS16212 Datasheet, PDF (3/5 Pages) Texas Instruments – 24-BIT FET BUS-EXCHANGE SWITCH WITH SCHOTTKY DIODE CLAMPING
SN74CBTS16212
24-BIT FET BUS-EXCHANGE SWITCH
WITH SCHOTTKY DIODE CLAMPING
SCDS036B – DECEMBER 1997 – REVISED MAY 1998
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Continuous channel current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Package thermal impedance, θJA (see Note 2): DGG package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81°C/W
DGV package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
DL package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions (see Note 3)
MIN MAX UNIT
VCC
VIH
VIL
TA
Supply voltage
High-level control input voltage
Low-level control input voltage
Operating free-air temperature
4 5.5 V
2
V
0.8 V
–40
85 °C
NOTE 3: All unused control inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP† MAX UNIT
VIK
VCC = 4.5 V,
II = –18 mA
–1.2 V
II
IIL
IIH
VCC = 5.5 V,
VCC = 5.5 V,
VI = GND
VI = 5.5 V
–1
µA
150
ICC
∆ICC§
VCC = 5.5 V,
Control inputs VCC = 5.5 V,
IO = 0,
VI = VCC or GND
One input at 3.4 V, Other inputs at VCC or GND
3 µA
2.5 mA
Ci
Control inputs VI = 3 V or 0
2.5
pF
Cio(OFF)
VO = 3 V or 0,
S0, S1, or S2 = VCC
10.5
pF
VCC = 4 V,
VI = 2.4 V,
II = 15 mA
20
ron¶
VCC = 4.5 V
VI = 0
II = 64 mA
II = 30 mA
4
7
Ω
4
7
VI = 2.4 V,
II = 15 mA
6
12
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ This is the increase in supply current for each input that is at the specified TTL voltage level rather than VCC or GND.
¶ Measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by
the lower of the voltages of the two (A or B) terminals.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3