RI-I16-112A-03 Datasheet, PDF (3/4 Pages) Texas Instruments – Tag-it™ HF-I PLUS TRANSPONDER INLAYS 24.2-mm CIRCULAR
RI-I16-112A-03
www.ti.com
SCBS826 – OCTOBER 2004 – REVISED DECEMBER 2005
SUPPORTED COMMAND SET
REQUEST
REQUEST MODE(1)
REQUEST CODE
INVENTORY ADDRESSED NON-ADDRESSED
SELECT
AFI
ISO 15693 Mandatory and Optional Commands
Inventory
0x01
ü
–
–
–
ü
Stay Quiet
0x02
–
ü
–
–
–
Read_Single_Block
0x20
ü
ü
ü
ü
ü
Write_Single_Block
0x21
–
ü
ü
ü
–
Lock_Block
0x22
–
ü
ü
ü
–
Read_Multi_Blocks
0x23
ü
ü
ü
ü
ü
Write_Multi_Blocks
0x24
–
–
–
–
–
Select Tag
0x25
–
ü
–
–
–
Reset to Ready
0x26
–
ü
ü
ü
–
Write_AFI
0x27
–
ü
ü
ü
–
Lock_AFI
0x28
–
ü
ü
ü
–
Write DSFID
0x29
–
ü
ü
ü
–
Lock DSFID
0x2A
–
ü
ü
ü
–
Get_System_info
0x2B
ü
ü
ü
ü
ü
Get_M_BLK_Sec_St
0x2C
ü
ü
ü
ü
ü
TI Custom Commands
Write_2_Blocks
0xA2
–
ü
ü
ü
–
Lock_2_Blocks
0xA3
–
ü
ü
ü
–
(1) ü = Implemented, – = Not applicable
MEMORY ORGANIZATION
32 bits
Block # 1
2
3
62
63
Submit Documentation Feedback