PTQA430025_0612 Datasheet, PDF (3/18 Pages) Texas Instruments – 100-W 48-V INPUT ISOLATED DC/DC CONVERTER | |||
|
◁ |
PTQA430025, PTQA430033, PTQA420050
www.ti.com
SLTS261A â MAY 2006 â REVISED DECEMBER 2006
ELECTRICAL CHARACTERISTICS PTQA430025
(Unless otherwise stated, TA =25°C, VI = 48 V, VO = 2.5 V, CO = 0 µF, and IO = IOmax)
PARAMETER
TEST CONDITIONS
IO
VI
VO tol
Output Current
Input Voltage Range
Set Point Voltage
Tolerance
Over VI range
Over IO Range
Regtemp
Regline
Regload
âVotot
Temperature Variation
Line Regulation
Load Regulation
Total Output Voltage
Variation
â40°C >TA > 85°C
Over VI range
Over IO range
Includes set-point, line, load, â40°C >TA > 85°C
âVADJ
η
VR
ttr
âVtr
ITRIP
OVP
Output Adjust Range
Efficiency
VO Ripple (pk-pk)
Transient Response
Overcurrent Threshold
Output Overvoltage
Protection
PO⤠75 W
IO = 50% IOmax
20 MHz bandwidth
0.1 A/µs slew rate, 50% to 75% IOmax
VO over/undershoot
Shutdown, followed by auto-recovery
Output shutdown and latch off
OTP
Over Temperature
Protection
Temperature Measurement at thermal sensor. Hysteresis = 10°C
nominal.
fs
Switching Frequency
UVLO Undervoltage Lockout
On/Off Input: Negative Enable
Over VI range
VOFF
VHYS
VI decreasing, IO = 6 A
Hysteresis
VIH
Input High Voltage
VIL
Input Low Voltage
IIL
Input Low Current
On/Off Input: Positive Enable
Referenced to âVI
VIH
Input High Voltage
VIL
Input Low Voltage
Referenced to âVI
IIL
Input Low Current
IISB
Standby Input Current
Output disabled (pin 2 status set to Off)
CI
External Input Capacitance Between +VI and âVI
CO
External Output
Capacitance
Between +VO and âVO
Isolation Voltage
Input-to-output and input-to-case
Isolation Capacitance
Input-to-output
Isolation Resistance
Input-to-output
PTQA430025
MIN TYP MAX UNIT
0
30 A
36
48
75 V
±1 (1)
%VO
±1.15
±5
±5
±1.5
%VO
mV
mV
±3 %VO
â20
91%
50
150
25
41
120
105
10 %VO
100 mVpp
µs
mV
A
%VO
°C
300
kHz
32.5
V
1.5
2.4
â0.2
Open (2)
V
0.8
â0.3
mA
4.5
â0.2
0
Open (2)
V
0.8
â0.5
mA
37
mA
100
µF
30000 µF
1500
Vdc
1200
pF
10
Mâ¦
(1) If Sense(â) is not used, pin 5 must be connected to pin 4 for optimum output voltage accuracy.
(2) The Remote On/Off input has an internal pull-up and may be controlled with an open collector (drain) interface. An open circuit
correlates to a logic high. Consult the application notes for interface considerations.
Submit Documentation Feedback
3
|
▷ |