English
Language : 

PTEA404120 Datasheet, PDF (3/14 Pages) Texas Instruments – 50-W, 48-V INPUT, 12-V OUTPUT, ISOLATED DC/DC CONVERTER
PTEA404120
www.ti.com
SLTS274A – DECEMBER 2006 – REVISED JANUARY 2007
ELECTRICAL CHARACTERISTICS PTEA404120
(Unless otherwise stated, TA =25°C, VI = 48 V, VO = 12 V, CO = 0 µF, and IO = IOmax)
PARAMETER
TEST CONDITIONS
IO
VI
VO tol
Output Current
Input Voltage Range
Set Point Voltage Tolerance
Over VI range
Over IO Range
Regtemp
Regline
Regload
∆Votot
∆VADJ
η
VR
ttr
∆Vtr
ITRIP
OVP
OTP
Temperature Variation
Line Regulation
Load Regulation
Total Output Voltage Variation
Output Adjust Range
Efficiency
VO Ripple (pk-pk)
Transient Response
Overcurrent Threshold
Output Overvoltage Protection
Over Temperature Protection
fs
UVLO
Switching Frequency
Undervoltage Lockout
On/Off Input: Negative Enable
VIH
Input High Voltage
VIL
Input Low Voltage
IIL
Input Low Current
On/Off Input: Positive Enable
VIH
Input High Voltage
VIL
Input Low Voltage
IIL
Input Low Current
IISB
Standby Input Current
CI
External Input Capacitance
CO
External Output Capacitance
Isolation Voltage
Isolation Capacitance
Isolation Resistance
–40°C >TA > 85°C
Over VI range
Over IO range
Includes set-point, line, load, –40°C >TA > 85°C
PO≤ 50 W and IO≤ 4.2 A
IO = IOmax
20 MHz bandwidth
0.1 A/µs slew rate, 50% to 75% IOmax
VO over/undershoot
Shutdown, followed by auto-recovery
Output shutdown and latch off
Temperature Measurement at thermal sensor. Hysteresis
= 10°C nominal.
Over VI range
VOFF
VHYS
VI decreasing, IO = 1 A
Hysteresis
Referenced to –VI
Referenced to –VI
Output disabled (pin 2 status set to Off)
Between +VI and –VI
Between +VO and –VO
Equivalent Series Resistance
Input-to-output and input-to-case
Input-to-output
Input-to-output
MIN
0
35
11.88
–40
2.4
–0.2
4.5
–0.2
0
0
10
10
TYP
48
±1 (1)
12
±1.15
±5
±5
±1.5
91%
50
500
200
7
120
115
MAX
4.2
75
12.12
±3
10
UNIT
A
V
%VO
V
%VO
mV
mV
%VO
%VO
mVpp
µs
mV
A
%VO
°C
250
kHz
32.5
V
1.5
Open (2)
V
0.8
–0.3
mA
Open (2)
V
0.8
–0.3
mA
10 mA
100
µF
1000 µF
mΩ
2000
Vdc
1200
pF
MΩ
(1) If Sense(–) is not used, pin 5 must be connected to pin 4 for optimum output voltage accuracy.
(2) The Remote On/Off input has an internal pull-up and may be controlled with an open collector (or open drain) interface. An open circuit
correlates to a logic high. Consult the application notes for interface considerations.
Submit Documentation Feedback
3