SLTS218B - SEPTEMBER 2003 - REVISED NOVEMBER 2004
Specifications (Unless otherwise stated, TA =25°C, VI =48 V, CI =0µF, CO =0 µF, and IO =50% Iomax)
Characteristic
Symbol
Conditions
Min
PTB48500A
Typ
Max
Units
Output Power
Output Current
Output Voltage
Temperature Variation
Line Regulation
Load Regulation
Cross Regulation
Efficiency
Vo Ripple (pk-pk)
Transient Response
Po1, Po2
Vo1 (3.3 V)
—
Vo2 (1.2 V)
—
—
—
19.8
8.4
W
Po total
Both outputs
—
—
28
W
Io1, Io2
Over VI range
Vo1 (3.3 V)
0
Vo2 (1.2 V)
0
—
—
6 (1)
7 (1)
A
Io1 + Io2
Total (both outputs)
0
—
13
A
Vo1
Inlcudes set point, line, load,
Vo2
–40 ≤ TA ≤ +85°C
3.2
3.3
1.16
1.2
3.4
1.24
V
∆Regtemp
–40° ≤TA ≤ +85°C, IO =IO min
Vo1
—
Vo2
—
±0.5
—
±0.8
—
%Vo
∆Regline
Over VI range
Vo1, Vo2
—
±1
±10
mV
∆Regload
Over IO range
Vo1, Vo2
—
±3
±12
mV
∆Regcross
IO min ≤ Io2 ≤ Iomax, Io1 =1 A
IO min ≤ Io1 ≤ Iomax, Io2 =1 A
∆Vo1
—
∆Vo2
—
—
—
10
10
mV
η
Io1, Io2 =Iomax
—
82
—
%
Vr
20 MHz bandwidth
Vo1
—
Vo2
—
20
20
50
50
mVpp
ttr
1 A/µs load step, 50% to 100% Iomax
—
30
—
µs
∆Vtr
Vo1, Vo2 over/undershoot
—
±2.0
—
%Vo
Over Current Threshold
Iotrip
VI =36 V,
reset followed by auto-recovery
Io1 + Io2
13.5
16
—
A
Output Voltage Adjust Range
Switching Frequency
Under-Voltage Lockout
On/Off Enable (pin 3)
Input High Voltage
Input Low Voltage
Input Low Current
Vadj
ƒs
VI on
VI off
VIH
VIL
IIL
Vo2 only
Over VI and IO ranges
VI increasing
VI decreasing
Referenced to –VI (pin 5)
-10
—
500
550
—
34
—
32
+3.6
—
–0.2
—
—
–1
+20
600
—
—
+75 (2)
+0.8
—
%Vo
kHz
V
V
mA
Standby Input Current
Internal Input Capacitance
External Output Capacitance
Reliability
II standby
CI
Co1
Co2
MTBF
pins 3 & 5 connected
Per Telcordia SR-332
50% stress, TA =40°C, ground benign
—
2
—
2
0 (3)
—
0 (3)
—
1.5
—
—
—
5,000
5,000
—
mA
µF
µF
106 Hrs
Notes: (1) See Safe Operating Area curves or contact the factory for the appropriate derating.
(2) The On/Off Enable (pin 3) has an internal pull-up and may be controlled with an open-collector (or open-drain) transistor. The input is diode protected
and may be connected to +VI. The maximum open-circuit voltage is 7 V. If it is left open circuit the converter will operate when input power is applied.
(3) An output capacitor is not required.
For technical support and further information visit http://power.ti.com