English
Language : 

OPA211-EP_15 Datasheet, PDF (3/26 Pages) Texas Instruments – 1.1nV/√Hz NOISE, LOW POWER, PRECISION OPERATIONAL AMPLIFIER
OPA211-EP
www.ti.com
5 PIN CONFIGURATIONS
SBOS638 – JUNE 2012
(1)
NC 1
-IN 2
+IN 3
V- 4
OPA211
MSOP-8
8 Shutdown(2)
7 V+
6 OUT
(1)
5 NC
(1) NC denotes no internal connection.
(2) Shutdown function:
• Device enabled: (V–) ≤ VSHUTDOWN ≤ (V+) – 3V
• Device disabled: VSHUTDOWN ≥ (V+) – 0.35V
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
5.1 ABSOLUTE MAXIMUM RATINGS(1)
Over operating free-air temperature range (unless otherwise noted).
Supply Voltage
Input Voltage
Input Current (Any pin except power-supply pins)
Output Short-Circuit(2)
Operating Temperature
Storage Temperature
Junction Temperature
ESD Ratings
Human Body Model (HBM)
Charged Device Model (CDM)
VS = (V+) – (V–)
(TA)
(TA)
(TJ)
VALUE
40
(V–) – 0.5 to (V+) + 0.5
±10
Continuous
–55 to +125
–65 to +150
200
3000
1000
UNIT
V
V
mA
°C
°C
°C
V
V
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not supported.
(2) Short-circuit to VS/2 (ground in symmetrical dual supply setups), one amplifier per package.
Copyright © 2012, Texas Instruments Incorporated
Product Folder Links: OPA211-EP
Submit Documentation Feedback
3