English
Language : 

MAX208 Datasheet, PDF (3/14 Pages) Texas Instruments – 5-V MULTICHANNEL RS-232 LINE DRIVER / RECEIVER WITH +-15-KV ESD PROTECTION
MAX208
5ĆV MULTICHANNEL RSĆ232 LINE DRIVER/RECEIVER
WITH ±15ĆkV ESD PROTECTION
SLLS596A − OCTOBER 2003 − REVISED JANUARY 2004
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 6 V
Positive charge pump voltage range, V+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC−0.3 V to 14 V
Negative charge pump voltage range, V− (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −14 V to 0.3 V
Supply voltage difference, V+ − V− (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 V
Input voltage range, VI: Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to V+ + 0.3 V
Receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±30 V
Output voltage range, VO: Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V− − 0.3 V to V+ + 0.3 V
Receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to VCC + 0.3 V
Short-circuit duration: DOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous
Package thermal impedance, θJA (see Notes 2 and 3): DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . 63°C/W
(see Notes 2 and 3): DW package . . . . . . . . . . . . . . . . . . . . . . . . . . 46°C/W
(see Notes 2 and 4): NT package . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W
Operating virtual junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltages are with respect to network GND.
2. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) − TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
4. The package thermal impedance is calculated in accordance with JESD 51-3.
recommended operating conditions (see Note 5 and Figure 4)
Supply voltage
VIH Driver high-level input voltage
VIL Driver low-level input voltage
Driver input voltage
VI
Receiver input voltage
TA Operating free-air temperature
NOTE 5: Test conditions are C1−C4 = 0.1 µF at VCC = 5 V ± 0.5 V.
DIN
DIN
DIN
MAX208C
MAX208I
MIN NOM
4.5
5
2.4
0
−30
0
−40
MAX
5.5
0.8
5.5
30
70
85
UNIT
V
V
V
V
°C
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Note 5 and Figure 4)
PARAMETER
TEST CONDITIONS
ICC Supply current
No load, VCC = 5 V,
TA = 25°C
NOTE 5: Test conditions are C1−C4 = 0.1 µF at VCC = 5 V ± 0.5 V.
MIN TYP MAX UNIT
11
20 mA
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3