English
Language : 

LM56_15 Datasheet, PDF (3/22 Pages) Texas Instruments – LM56 Dual Output Low Power Thermostat
LM56
www.ti.com
SNIS120G – APRIL 2000 – REVISED FEBRUARY 2013
Absolute Maximum Ratings(1)
Input Voltage
Input Current at any pin(2)
Package Input Current(2)
Package Dissipation at TA = 25°C(3)
ESD Susceptibility(4)
Human Body Model - Pin 3 Only
All other pins
Machine Model
Storage Temperature
12V
5 mA
20 mA
900 mW
800V
1000V
125V
−65°C to + 150°C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see
the LM56 Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance
characteristics may degrade when the device is not operated under the listed test conditions.
(2) When the input voltage (VI) at any pin exceeds the power supply (VI < GND or VI > V+), the current at that pin should be limited to 5 mA.
The 20 mA maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input
current of 5 mA to four.
(3) The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature),
θJA (junction to ambient thermal resistance) and TA (ambient temperature). The maximum allowable power dissipation at any
temperature is PD = (TJmax–TA)/θJA or the number given in the Absolute Maximum Ratings, whichever is lower. For this device, TJmax =
125°C. For this device the typical thermal resistance (θJA) of the different package types when board mounted follow:
(4) The human body model is a 100 pF capacitor discharge through a 1.5 kΩ resistor into each pin. The machine model is a 200 pF
capacitor discharged directly into each pin.
Operating Ratings(1)(2)(3)
Operating Temperature Range
LM56BIM, LM56CIM
Positive Supply Voltage (V+)
TMIN ≤ TA ≤ TMAX
−40°C ≤ TA ≤ +125°C
+2.7V to +10V
Maximum VOUT1 and VOUT2
+10V
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see
the LM56 Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance
characteristics may degrade when the device is not operated under the listed test conditions.
(2) Soldering process must comply with Reflow Temperature Profile specifications. Refer to http://www.ti.com/packaging.
(3) Reflow temperature profiles are different for lead-free and non-lead-free packages.
Package Type
D0008A
DGK0008A
θJA
110°C/W
250°C/W
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM56
Submit Documentation Feedback
3