English
Language : 

CDC340 Datasheet, PDF (3/7 Pages) Texas Instruments – 1-LINE TO 8-LINE CLOCK DRIVER
CDC340
1-LINE TO 8-LINE CLOCK DRIVER
SCAS332B – DECEMBER 1992 – REVISED MAY 1997
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Voltage range applied to any output in the high state or power-off state,
VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –18 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2): DW package . . . . . . . . . . . . . . . . . . 1.6 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
For more information, refer to the Package Thermal Considerations Application Note in the ABT Advanced BiCMOS Technology
Data Book, literature number SCBD002.
recommended operating conditions (see Note 3)
VCC
VIH
VIL
VI
IOH
IOL
fclock
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
High-level output current
Low-level output current
Input clock frequency
One output back loaded
Both output banks loaded
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
MIN MAX UNIT
4.75 5.25 V
2
V
0.8 V
0 VCC V
– 48 mA
48 mA
80
MHz
40
0
70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA = 25°C
MIN TYP‡ MAX
VIK
VOH
VOL
II
IO§
ICC
VCC = 4.75 V,
VCC = 4.75 V,
VCC = 5 V,
VCC = 4.75 V,
VCC = 4.75 V,
VCC = 5.25 V,
VCC = 5.25 V,
VCC = 5.25 V,
VI = VCC or GND
II = –18 mA
IOH = – 3 mA
IOH = – 3 mA
IOH = – 48 mA
IOL = 48 mA
VI = VCC or GND
VO = 2.5 V
IO = 0,
Outputs high
Outputs low
–1.2
2.5
3
2
±1
– 50 – 100 – 200
2
24
Ci
VI = 2.5 V or 0.5 V
3
‡ All typical values are at VCC = 5 V.
§ No more than one output should be tested at a time, and the duration of the test should not exceed one second.
MIN MAX UNIT
–1.2 V
2.5
3
V
2
0.5 V
± 1 µA
– 50 – 200 mA
3.5
mA
33
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265