recommended operating conditions (see Note 3)
VCC
VIH
VIL
VI
IOH
IOL
∆t / ∆v
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
High-level output current
Low-level output current
Input transition rise or fall rate
fclock Input clock frequency
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
CDC329A
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS328B – DECEMBER 1992 – REVISED OCTOBER 1998
MIN NOM MAX UNIT
4.75
5 5.25 V
2
V
0.8 V
0
VCC V
– 32 mA
32 mA
5 ns / V
80 MHz
– 40
85 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VOL
II
ICC
VCC = 4.75 V,
VCC = 4.75 V,
VCC = 4.75 V,
VCC = 5.25 V,
VCC = 5.25 V,
TEST CONDITIONS
II = –18 mA
IOH = – 32 mA
IOL = 32 mA
VI = VCC or GND
VI = VCC or GND, IO = 0,
Outputs high
Outputs low
MIN TYP†
3.85
MAX
–1.2
0.55
±1
10
40
UNIT
V
V
V
µA
mA
Ci
VI = 2.5 V or 0.5 V
† All typical values are at VCC = 5 V, TA = 25°C
3
pF
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (see Figures 1 and 2)
PARAMETER
tPLH
tPHL
tPLH
tPHL
tsk(o)
tr
tf
FROM
(INPUT)
A
T/C
A
TO
(OUTPUT)
Any Y
Any Y
Any Y (same phase)
Any Y (any phase)
MIN TYP MAX UNIT
2
5.9
ns
1.7
5.9
1.5
5
ns
1.5
5
0.6
ns
1.5
1.3
ns
0.85
ns
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265