English
Language : 

CD74AC05M96G4 Datasheet, PDF (3/13 Pages) Texas Instruments – HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
CD54AC05, CD74AC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS306C – JANUARY 2001 –REVISED JUNE 2002
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN MAX
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
1.5 V
0.1
0.1
0.1
IOL = 50 µA
3V
0.1
0.1
0.1
4.5 V
0.1
0.1
0.1
VOL
VI = VIH or VIL
IOL = 12 mA
3V
0.36
0.44
0.5 V
IOL = 24 mA
IOL = 50 mA†
IOL = 75 mA†
4.5 V
5.5 V
5.5 V
0.36
0.44
0.5
1.65
1.65
II
VI = VCC or GND
5.5 V
±0.1
±1
±1 µA
ICC
VI = VCC or GND,
IO = 0
5.5 V
4
40
80 µA
Ci
10
10
10 pF
† Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive capability at 125°C.
switching characteristics over recommended operating free-air temperature range,
VCC = 1.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
tPLZ
A
tPZL
94
103
Y
ns
74
81
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
tPLZ
A
tPZL
3 10.4 2.9 11.5
Y
ns
2.3 8.3 2.3 9.1
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
tPLZ
A
tPZL
2.2 7.5 2.1 8.2
Y
ns
1.7 5.9 1.6 6.5
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance
TYP UNIT
105 pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3