English
Language : 

CD54HC4017F Datasheet, PDF (3/12 Pages) Texas Instruments – DECADE COUNTER/DIVIDER WITH TEN DECODED OUTPUTS
CD54HC4017
DECADE COUNTER/DIVIDER
WITH TEN DECODED OUTPUTS
SGDS011 – MAY 1999
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Input clamp current, IIK (VI < 0 V or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 V or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Continuous output current, each output pin, IO (VO > –0.5 V or VO < VCC + 0.5 V) . . . . . . . . . . . . . . ±25 mA
VCC or ground current, ICC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating (see Note 1)
MIN MAX UNIT
VCC Supply voltage
2
6V
VCC = 2 V
1.5
VIH High-level input voltage
VCC = 4.5 V
3.15
V
VCC = 6 V
4.2
VCC = 2 V
0 0.5
VIL
Low-level input voltage
VCC = 4.5 V
0 1.35 V
VCC = 6 V
0 1.8
VI
Input voltage
0 VCC V
VO
Output voltage
0 VCC V
VCC = 2 V
0 1000
tt
Input transition (rise and fall) time
VCC = 4.5 V
0 500 ns
VCC = 6 V
0 400
TA
Operating free-air temperature
–55 125 °C
NOTE 1: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to TI application report Implications
of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VOH
CMOS loads
TTL loads
VI = VIH or VIL,
VI = VIH or VIL
VOL
II
ICC
Ci
CMOS loads
TTL loads
VI = VIH or VIL,
VI = VIH or VIL
VI = VCC or 0
VI = VCC or 0,
IOH = –0.02 mA
IOH = –4 mA
IOH = –5.2 mA
IOL = 0.02 mA
IOL = 4 mA
IOL = 5.2 mA
IO = 0
VCC
2V
4.5 V
6V
4.5 V
6V
2V
4.5 V
6V
4.5 V
6V
6V
6V
2 V to 6 V
TA = 25°C
MIN MAX
1.9
4.4
5.9
3.98
5.48
0.1
0.1
0.1
0.26
0.26
±100
8
10
MIN MAX UNIT
1.9
4.4
5.9
V
3.7
5.2
0.1
0.1
0.1 V
0.4
0.4
±1000 nA
160 µA
10 pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265