English
Language : 

CD54ACT08 Datasheet, PDF (3/9 Pages) Texas Instruments – QUADRUPLE 2-INPUT POSITIVE-AND GATES
CD54ACT08, CD74ACT08
QUADRUPLE 2-INPUT POSITIVE-AND GATES
ACT INPUT LOAD TABLE
INPUT UNIT LOAD
A or B
0.3
Unit load is ∆ICC limit specified
in electrical characteristics
table (e.g., 2.4 mA at 25°C).
SCHS312B – JANUARY 2001 – REVISED JUNE 2002
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
tPLH
tPHL
A or B
3.3 11.7 3.2 12.9
Y
ns
3.3 11.7 3.2 12.9
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance
TYP UNIT
50 pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3