English
Language : 

CD54AC02 Datasheet, PDF (3/13 Pages) Texas Instruments – QUADRUPLE 2-INPUT POSITIVE-NOR GATES
CD54AC02, CD74AC02
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SCHS304C – JANUARY 2001 – REVISED JUNE 2002
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN MAX
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
1.5 V
1.4
1.4
1.4
IOH = –50 µA
3V
2.9
2.9
2.9
4.5 V
4.4
4.4
4.4
VOH
VI = VIH or VIL
IOH = –4 mA
IOH = –24 mA
IOH = –50 mA†
IOH = –75 mA†
3 V 2.58
2.48
2.4
V
4.5 V 3.94
3.8
3.7
5.5 V
3.85
5.5 V
3.85
1.5 V
0.1
0.1
0.1
IOL = 50 µA
3V
0.1
0.1
0.1
4.5 V
0.1
0.1
0.1
VOL
VI = VIH or VIL
IOL = 12 mA
3V
0.36
0.44
0.5 V
IOL = 24 mA
IOL = 50 mA†
IOL = 75 mA†
4.5 V
5.5 V
5.5 V
0.36
0.44
0.5
1.65
1.65
II
VI = VCC or GND
5.5 V
±0.1
±1
±1 µA
ICC
VI = VCC or GND,
IO = 0
5.5 V
4
40
80 µA
Ci
10
10
10 pF
† Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive capability at 125°C.
switching characteristics over recommended operating free-air temperature range,
VCC = 1.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
tPLH
tPHL
A or B
131
144
Y
ns
131
144
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
tPLH
tPHL
A or B
4.1 14.6
4 16.1
Y
ns
4.1 14.6
4 16.1
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3