PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN TYP MAX
MIN MAX
IOH = â50 mA
4.5 V 4.4
4.4
5.5 V 5.4
5.4
VOH
IOH = â24 mA
4.5 V 3.94
3.8
5.5 V 4.94
4.8
IOH = â75 mAâ
IOL = 50 mA
5.5 V
4.5 V
5.5 V
3.85
0.1
0.1
0.1
0.1
VOL
IOL = 24 mA
4.5 V
5.5 V
0.36
0.44
0.36
0.44
II
ICC
âICCâ¡
IOL = 75 mAâ
VI = VCC or GND
VI = VCC or GND,
One input at 3.4 V,
IO = 0
Other inputs at GND or VCC
5.5 V
5.5 V
5.5 V
5.5 V
1.65
±0.1
±1
4
40
0.9
1
Ci
VI = VCC or GND
5V
3.5
â Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ns.
â¡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
UNIT
V
V
mA
mA
mA
pF
switching characteristics over recommended ranges of supply voltage and free-air temperature
(unless otherwise noted) (see Figure 1)
PARAMETER
tPLH
tPHL
FROM
(INPUT)
A
TO
(OUTPUT)
Y
TA = 25°C
MIN TYP MAX
1.5 5.3
9
1.5 6.4 8.7
MIN MAX UNIT
1.5 9.7
ns
1.5 9.6
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance per inverter
TEST CONDITIONS
CL = 50 pF, f = 1 MHz
TYP UNIT
32 pF