English
Language : 

74ACT11004 Datasheet, PDF (3/5 Pages) Texas Instruments – HEX INVERTER
74ACT11004
HEX INVERTER
SCAS215B – JANAURY 1988 – REVISED JUNE 1997
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN TYP MAX
MIN MAX
IOH = –50 mA
4.5 V 4.4
4.4
5.5 V 5.4
5.4
VOH
IOH = –24 mA
4.5 V 3.94
3.8
5.5 V 4.94
4.8
IOH = –75 mA†
IOL = 50 mA
5.5 V
4.5 V
5.5 V
3.85
0.1
0.1
0.1
0.1
VOL
IOL = 24 mA
4.5 V
5.5 V
0.36
0.44
0.36
0.44
II
ICC
∆ICC‡
IOL = 75 mA†
VI = VCC or GND
VI = VCC or GND,
One input at 3.4 V,
IO = 0
Other inputs at GND or VCC
5.5 V
5.5 V
5.5 V
5.5 V
1.65
±0.1
±1
4
40
0.9
1
Ci
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ns.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
UNIT
V
V
mA
mA
mA
pF
switching characteristics over recommended ranges of supply voltage and free-air temperature
(unless otherwise noted) (see Figure 1)
PARAMETER
tPLH
tPHL
FROM
(INPUT)
A
TO
(OUTPUT)
Y
TA = 25°C
MIN TYP MAX
1.5 5.3
9
1.5 6.4 8.7
MIN MAX UNIT
1.5 9.7
ns
1.5 9.6
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance per inverter
TEST CONDITIONS
CL = 50 pF, f = 1 MHz
TYP UNIT
32 pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3