English
Language : 

74AC11011 Datasheet, PDF (3/5 Pages) Texas Instruments – TRIPLE 3-INPUT POSITIVE-AND GATES
54AC11011, 74AC11011
TRIPLE 3-INPUT POSITIVE-AND GATES
recommended operating conditions
VCC Supply voltage
VIH
High-level input voltage
VIL
Low-level input voltage
VI
Input voltage
VO
Output voltage
IOH
High-level output current
IOL
Low-level output current
∆t /∆v
TA
Input transition rise or fall rate
Operating free-air temperature
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
SCAS029A – JULY 1987 – REVISED APRIL 1993
54AC11011
MIN NOM MAX
3
5 5.5
2.1
3.15
3.85
0.9
1.35
1.65
0
VCC
0
VCC
–4
– 24
– 24
12
24
24
0
10
– 55
125
74AC11011
MIN NOM MAX
3
5 5.5
2.1
3.15
3.85
0.9
1.35
1.65
0
VCC
0
VCC
–4
– 24
– 24
12
24
24
0
10
– 40
85
UNIT
V
V
V
V
V
mA
mA
ns/ V
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
54AC11011
MIN TYP MAX MIN MAX
3V
2.9
2.9
IOH = – 50 µA
4.5 V
4.4
4.4
5.5 V
5.4
5.4
VOH
IOH = – 4 mA
IOH = – 24 mA
IOH = – 50 mA†
IOH = – 75 mA†
3 V 2.58
4.5 V 3.94
5.5 V 4.94
5.5 V
5.5 V
3V
2.4
3.7
4.7
3.85
0.1
0.1
IOL = 50 µA
4.5 V
5.5 V
0.1
0.1
0.1
0.1
VOL
IOL = 12 mA
IOL = 24 mA
3V
4.5 V
5.5 V
0.36
0.5
0.36
0.5
0.36
0.5
IOL = 50 mA†
5.5 V
1.65
IOL = 75 mA†
5.5 V
II
VI = VCC or GND
5.5 V
± 0.1
±1
ICC
VI = VCC or GND,
IO = 0
5.5 V
4
80
Ci
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
74AC11011
MIN MAX
2.9
4.4
5.4
2.48
3.8
4.8
3.85
0.1
0.1
0.1
0.44
0.44
0.44
1.65
±1
40
UNIT
V
V
µA
µA
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
2–3