Load
RL
VL= VIN
To APA
GND
RC Low-Pass Filters
RFILT
RFILT
CFILT
VOUT
CFILT
AP Analyzer Input
CANA
RANA
CANA
RANA
Figure 34. Measurement Low-Pass Filter Derivation Circuit-Class-D APAs
The transfer function for this circuit is shown in Equation 5 where ωO = REQCEQ, REQ = RFILT || RANA and
CEQ = (CFILT + CANA). The filter frequency should be set above fMAX, the highest frequency of the measurement
bandwidth, to avoid attenuating the audio signal. Equation 6 provides this cutoff frequency, fC. The value of RFILT
must be chosen large enough to minimize current that is shunted from the load, yet small enough to minimize the
attenuation of the analyzer-input voltage through the voltage divider formed by RFILT and RANA. A general rule is
that RFILT should be small (~100 Ω) for most measurements. This reduces the measurement error to less than
1% for RANA ≥ 10 kΩ.
( VOUT
VIN
)=
( ) RANA
RANA + RFILT
( )w
1 + j wO
(5)
fc = Ö2 x fmax
(6)
An exception occurs with the efficiency measurements, where RFILT must be increased by a factor of ten to
reduce the current shunted through the filter. CFILT must be decreased by a factor of ten to maintain the same
cutoff frequency. See Table 3 for the recommended filter component values.
Once fC is determined and RFILT is selected, the filter capacitance is calculated using . When the calculated value
is not available, it is better to choose a smaller capacitance value to keep fC above the minimum desired value
calculated in Equation 7.
1
CFILT = 2p x fc x RFILT
(7)
Table 3 shows recommended values of RFILT and CFILT based on common component values. The value of fC
was originally calculated to be 28 kHz for an fMAX of 20 kHz. CFILT, however, was calculated to be 57,000 pF, but
the nearest values of 56,000 pF and 51,000 pF were not available. A 47,000-pF capacitor was used instead, and
fC is 34 kHz, which is above the desired value of 28 kHz.
Table 3. Typical RC Measurement Filter Values
MEASUREMENT
Efficiency
All other measurements
RFILT
1000 Ω
100 Ω
CFILT
5,600 pF
56,000 pF
28