English
Language : 

TS5A3159A_15 Datasheet, PDF (21/34 Pages) Texas Instruments – TS5A3159A 1-Ω SPDT Analog Switch 5-V and 3.3-V Single-Channel 2:1 Multiplexer and Demultiplexer
www.ti.com
12 Device and Documentation Support
TS5A3159A
SCDS200D – JUNE 2005 – REVISED JUNE 2015
12.1 Device Support
12.1.1 Device Nomenclature
SYMBOL
VCOM
VNC
VNO
ron
rpeak
Δron
ron(flat)
INC(OFF)
INC(PWROFF)
INO(OFF)
INO(PWROFF)
INC(ON)
INO(ON)
ICOM(ON)
ICOM(PWROFF)
VIH
VIL
VI
IIH, IIL
tON
tOFF
tBBM
QC
CNC(OFF)
CNO(OFF)
CNC(ON)
CNO(ON)
CCOM(ON)
CIN
OISO
XTALK
Table 2. Parameter Description
DESCRIPTION
Voltage at COM
Voltage at NC
Voltage at NO
Resistance between COM and NC or COM and NO ports when the channel is on
Peak ON-state resistance over a specified voltage range
Difference of ron between channels
Difference between the maximum and minimum value of ron in a channel over the specified range of conditions
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the off state under
worst-case input and output conditions
Leakage current measured at the NC port during the power-down condition, V+ = 0
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the off state under
worst-case input and output conditions
Leakage current measured at the NO port during the power-down condition, V+ = 0
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the on state and the
output (COM) being open
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the on state and the
output (COM) being open
Leakage current measured at the COM port, with the corresponding channel (COM to NO or COM to NC) in the on
state and the output (NC or NO) being open
Leakage current measured at the COM port during the power-down condition, V+ = 0
Minimum input voltage for logic high for the control input (IN)
Maximum input voltage for logic low for the control input (IN)
Voltage at (IN)
Leakage current measured at (IN)
Turnon time for the switch. This parameter is measured under the specified range of conditions and by the
propagation delay between the digital control (IN) signal and analog outputs (COM, NC, or NO) signal when the
switch is turning on.
Turnoff time for the switch. This parameter is measured under the specified range of conditions and by the
propagation delay between the digital control (IN) signal and analog outputs (COM, NC, or NO) signal when the
switch is turning off.
Break-before-make time. This parameter is measured under the specified range of conditions and by the
propagation delay between the output of two adjacent analog channels (NC and NO) when the control signal
changes state.
Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NC, NO,
or COM) output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the
control input. Charge injection, QC = CL × ΔVO, CL is the load capacitance and ΔVO is the change in analog output
voltage.
Capacitance at the NC port when the corresponding channel (NC to COM) is off
Capacitance at the NO port when the corresponding channel (NO to COM) is off
Capacitance at the NC port when the corresponding channel (NC to COM) is on
Capacitance at the NO port when the corresponding channel (NO to COM) is on
Capacitance at the COM port when the corresponding channel (COM to NC or COM to NO) is on
Capacitance of (IN)
OFF isolation of the switch is a measurement OFF-state switch impedance. This is measured in dB in a specific
frequency, with the corresponding channel (NC to COM or NO to COM) in the off state.
Crosstalk is a measurement of unwanted signal coupling from an on channel to an off channel (NC to NO or NO to
NC). This is measured in a specific frequency and in dB.
Copyright © 2005–2015, Texas Instruments Incorporated
Product Folder Links: TS5A3159A
Submit Documentation Feedback
21