English
Language : 

MSP430C32X_10 Datasheet, PDF (21/35 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430C32x, MSP430P325A
MIXED SIGNAL MICROCONTROLLER
SLAS219B − MARCH 1999 − REVISED MARCH 2000
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted) (continued)
JTAG
PARAMETER
f(TCK)
R(TEST)
JTAG/Test
TEST CONDITIONS
TCK frequency
Pullup resistors on TMS, TCK, TDI
(see Note 20)
VCC = 3 V
VCC = 5 V
VCC = 3 V/ 5 V
MIN TYP MAX UNIT
DC
5
MHz
DC
10
25
60
90 kΩ
V(FB)
I(FB)
t(FB)
V(PP)
I(PP)
t(pps)
t(ppf)
Pn
t(erase)
Fuse blow voltage, C versions (see Note 22) VCC = 3 V/ 5 V
5.5
Fuse blow voltage, E/P versions
JTAG/Fuse (see Note 21) (see Note 22)
VCC = 3 V/ 5 V
11
Supply current on TDI to blow fuse
Time to blow the fuse
Programming voltage, applied to TDI/VPP
12 12.5
Current from programming voltage source
EPROM (E) and OTP(P) − Programming time, single pulse
versions only
Programming time, fast algorithm
5
100
Number of pulses for successful programming
4
EPROM (E) versions only
Data retention TJ < 55°C
Erase time wave length 2537 Å at 15 Ws/cm2
(UV lamp of 12 mW/ cm2)
Write/Erase cycles
10
30
1000
6
V
12
100 mA
1 ms
13 V
70 mA
ms
μs
100
year
min
cycles
NOTES: 20. The TMS and TCK pullup resistors are implemented in all C-, P-, and E-versions. The pullup resistor on TDI is implemented in
C-versions only.
21. Once the JTAG fuse is blown, no further access to the MSP430 JTAG/test feature is possible. The JTAG block switches to by-pass
mode.
22. The voltage supply to blow the JTAG fuse is applied to TDI/VPP pin when fuse blowing is desired.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
21