UCC5640PW Datasheet, PDF (2/13 Pages) Texas Instruments – LOW VOLTAGE DIFFERENTIAL (LVD) SCSI 9-LINE TERMINATOR | |||
|
◁ |
UCC5640
SLUS314C â JANUARY 2000 â REVISED JUNE 2003
ORDERING INFORMATION
PACKAGED DEVICE{
TA
TSSOP-24 (PW)
TSSOP-28 (PW)
0°C to 70°C
UCC5640PW24
UCC5640PW28
â The TSSOP packages are available taped and reeled. Add TR suffix to device type (e.g.
UCC5640PW24TR) to order quantities of 2,000 devices per reel.
CONNECTION DIAGRAM
TSSOPâ24 (Top View)
PW Package
TSSOPâ28 (Top View)
PW Package
REG 1
L1+ 2
L1â 3
L2+ 4
L2â 5
L3+ 6
L3â 7
L4+ 8
L4â 9
DIFFB 10
DIFSENS 11
GND 12
24 TRMPWR
23 L9â
22 L9+
21 L8â
20 L8+
19 L7â
18 L7+
17 L6â
16 L6+
15 L5â
14 L5+
13 DISCNCT
REG 1
N/C 2
L1+ 3
L1â 4
L2+ 5
L2â 6
L3+ 7
L3â 8
L4+ 9
L4â 10
DIFFB 11
DIFSENS12
N/C 13
GND 14
28 TRMPWR
27 LVD
26 L9â
25 L9+
24 L8â
23 L8+
22 L7â
21 L7+
20 L6â
19 L6+
18 L5â
17 L5+
16 N/C
15 DISCNCT
RECOMMENDED OPERATING CONDITIONS
TRMPWR voltage
Signal line voltage
Disconnect input voltage
MIN
2.7
0
0
NOM MAX
5.25
3.6
TRMPWR
UNIT
V
°C
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted{}
UCC5640
UNIT
TRMPWR voltage
Signal line voltage
6
V
0 to 3.6
Package dissipation
1
W
Storage temperature, Tstg
â65 to 150
Operating junction temperature, TJ
â55 to 150
°C
Lead temperature (soldering, 10 sec.)
300
â Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is
not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. All voltages are with respect
to GND. Currents are positive into and negative out of, the specified terminal.
â¡ Currents are positive into, negative out of the specified terminal. Consult Packaging Section of Databook for thermal limitations and
considerations of packages. All voltages are referenced to GND.
2
www.ti.com
|
▷ |