English
Language : 

TPS62262DDCT Datasheet, PDF (2/32 Pages) Texas Instruments – 2.25 MHz 600 mA Step Down Converter in 2x2 QFN / TSOT-23 Package
TPS62260, TPS62261
TPS62262, TPS62263
SLVS763D – JUNE 2007 – REVISED FEBRUARY 2011
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
TA
PART NUMBER
OUTPUT
VOLTAGE (1)
PACKAGE (2)
PACKAGE
DESIGNATOR
TPS62260
Adjustable
QFN 2x2-6
TSOT-23 5
DRV
DDC
–40°C to 85°C
TPS62261
TPS62262
1.8V fixed
1.2V fixed
QFN 2x2-6
QFN 2x2-6
TSOT-23 5
DRV
DRV
DDC
TPS62263
2.5V fixed
QFN 2x2-6
DRV
MODE PIN
Yes
No, PFM/PWM
auto transition
Yes
Yes
No, PFM/PWM
auto transition
Yes
PACKAGE
MARKING
BYK
BYP
BYL
BYM
QXS
CFX
(1) Contact TI for other fixed output voltage options
(2) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1)
Input voltage range(2)
Voltage range at EN, MODE
Voltage on SW
Peak output current
ESD rating(3)
HBM Human body model
CDM Charge device model
Machine model
TJ
Maximum operating junction temperature
Tstg Storage temperature range
VALUE
–0.3 to 7
–0.3 to VIN +0.3, ≤ 7
–0.3 to 7
Internally limited
2
1
200
–40 to 125
–65 to 150
UNIT
V
A
kV
V
°C
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network ground terminal.
(3) The human body model is a 100-pF capacitor discharged through a 1.5-kΩ resistor into each pin. The machine model is a 200-pF
capacitor discharged directly into each pin.
DISSIPATION RATINGS
PACKAGE
DRV
RθJA
76°C/W
DDC
250/°C
POWER RATING FOR TA ≤ 25°C
1300 mW
400 mW
DERATING FACTOR ABOVE TA = 25°C
13 mW/°C
4 mW/°C
RECOMMENDED OPERATING CONDITIONS
VIN Supply voltage
Output voltage range for adjustable voltage
TA Operating ambient temperature
TJ Operating junction temperature
MIN NOM MAX UNIT
2
6V
0.6
VIN V
–40
85 °C
–40
125 °C
2
Submit Documentation Feedback
© 2007–2011, Texas Instruments Incorporated