English
Language : 

TL7759 Datasheet, PDF (2/6 Pages) Texas Instruments – SUPPLY-VOLTAGE SUPERVISORS
TL7759
SUPPLY-VOLTAGE SUPERVISORS
SLVS042D – JANUARY 1991 – REVISED JULY 1999
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Off-state output voltage range: RESET voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 20 V
RESET voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 20 V
Low-level output current, IOL (RESET) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
High-level output current, IOH (RESET) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –10 mA
Package thermal impedance, θJA (see Notes 2 and 3): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
P package . . . . . . . . . . . . . . . . . . . . . . . . . . . 127°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . 149°C/W
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to the network ground terminal.
2. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can impact reliability.
3. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace
length of zero.
recommended operating conditions
Supply voltage, VCC
Output voltage, VO (see Note 4)
Low-level output current, IOL
High-level output current, IOH
Operating free-air temperature, TA
NOTE 4: RESET output must not be pulled down below GND potential.
Transistor off RESET voltage
Transistor off RESET voltage
RESET
RESET
TL7759C
MIN MAX UNIT
1
7V
15
V
0
24 mA
–8 mA
0
70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TL7759C
MIN TYP‡ MAX
VOL
VOH
Low-level output voltage
High-level output voltage
RESET
RESET
VCC = 4.3 V
IOL = 24 mA
IOH = –8 mA
0.4 0.8
VCC–1
VIT–
Input threshold voltage
(negative-going VCC)
TA = 25°C
TA = 0°C to 70°C
4.43 4.55 4.67
4.4
4.7
Vres§ Power-up reset voltage
RL = 2.2 kΩ
TA = 25°C
TA = 0°C to 70°C
0.8
1
1.2
Vhys¶ Hysteresis at VCC input
TA = 25°C
TA = 0°C to 70°C
40
50
60
30
70
IOH High-level output current RESET
IOL
Low-level output current RESET
VCC = 7 V, See Figure 1
VOH = 15 V
VOL = 0 V
1
–1
ICC Supply current
No load
VCC = 4.3 V
VCC = 5.5 V
1400 2000
40
‡ Typical values are at TA = 25°C.
§ This is the lowest voltage at which RESET becomes active, VCC slew rate ≤ 5 V/µs.
¶ This is the difference between positive-going input threshold voltage, VIT+, and negative-going input threshold voltage, VIT–.
UNIT
V
V
V
V
mV
µA
µA
µA
2