English
Language : 

TL430_06 Datasheet, PDF (2/9 Pages) Texas Instruments – ADJUSTABLE SHUNT REGULATORS
TL430
ADJUSTABLE SHUNT REGULATORS
SLVS050D − JUNE 1976 − REVISED JANUARY 2005
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Regulator voltage (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 V
Continuous regulator current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 mA
Package thermal impedance, θJA (see Notes 2 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140°C/W
Operating virtual junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to the anode terminal.
2. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) − TA)/θJA. Operating at the absolute maximum TJ of 150°C can impact reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
VZ Regulator voltage
IZ
Regulator current
TA
Operating free-air temperature range
TL430C
MIN MAX UNIT
Vref
30 V
2 100 mA
0
70 °C
electrical characteristics over recommended operating conditions, TA = 25°C (unless otherwise
noted)
PARAMETER
TEST
FIGURE
TEST CONDITIONS
TL430C
UNIT
MIN TYP MAX
VI(ref)
Reference input voltage
1
VZ = VI(ref),
IZ = 10 mA
2.5 2.75
3V
αVI(ref)
Temperature coefficient of reference input
voltage
1
VZ = VI(ref),
TA = 0°C to 70°C
IZ = 10 mA,
120
ppm/°C
II(ref)
Reference input current
2
IZ = 10 mA,
R2 = ∞
R1 = 10 kΩ,
3
10 µA
IZK
Regulator current near lower knee of
regulation range
1
VZ = VI(ref)
0.5
2 mA
IZK
rz
Vn
NOTES:
Regulator current at maximum
1
VZ = VI(ref)
50
limit of regulation range
mA
2
VZ = 5 V to 30 V, See Note 4
100
Differential regulator resistance
(see Note 5)
1
VZ = VI(ref),
∆IZ = (52 − 2) mA
1.5
3Ω
VZ = 3 V
50
Noise voltage
2
f = 0.1 Hz to 10 Hz VZ = 12 V
200
µV
VZ = 30 V
650
4. The average power dissipation, VZ • IZ • duty cycle, must not exceed the maximum continuous rating in any 10-ms interval.
5. The regulator resistance for VZ > VI(ref), rz, is given by:
ǒ Ǔ rzȀ
+
rz
1
)
R1
R2
2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265