absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Regulator voltage (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 V
Continuous regulator current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 mA
Package thermal impedance, θJA (see Notes 2 and 3): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156°C/W
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to the anode terminal.
2. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can impact reliability.
3. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace
length of zero.
recommended operating conditions
Regulator voltage, VZ
Regulator current, IZ
Operating free-air temperature range, TA
TL430C
MIN MAX UNIT
Vref
30 V
2 100 mA
0
70 °C
electrical characteristics over recommended operating conditions, TA = 25°C (unless otherwise
noted)
VI(ref)
αVI(ref)
II(ref)
PARAMETER
Reference input voltage
Temperature coefficient of reference input
voltage
Reference input current
TEST
FIGURE
1
1
2
TEST CONDITIONS
VZ = VI(ref),
VZ = VI(ref),
TA = 0°C to 70°C
IZ = 10 mA,
R2 = ∞
IZ = 10 mA
IZ = 10 mA,
R1 = 10 kΩ,
TL430C
MIN TYP MAX
2.5 2.75
3
UNIT
V
120
ppm/°C
3
10 µA
IZK
Regulator current near lower knee of
regulation range
1
VZ = VI(ref)
0.5
2 mA
IZK
Regulator current at maximum
limit of regulation range
1
VZ = VI(ref)
50
2
VZ = 5 V to 30 V, See Note 4
100
mA
rz
Differential regulator resistance
(see Note 5)
1
VZ = VI(ref),
∆IZ = (52 – 2) mA
1.5
3W
VZ = 3 V
50
Vn
Noise voltage
2
f = 0.1 Hz to 10 Hz VZ = 12 V
200
µV
VZ = 30 V
650
NOTES: 4. The average power dissipation, VZ • IZ • duty cycle, must not exceed the maximum continuous rating in any 10-ms interval.
Ȁ + ǒ ) Ǔ 5. The regulator resistance for VZ > VI(ref), rz, is given by:
rz
rz 1
R1
R2
2