English
Language : 

SN75LBC773 Datasheet, PDF (2/13 Pages) Texas Instruments – GEOPORTE TRANSCEIVER
SN75LBC773
GEOPORT™ TRANSCEIVER
SLLS247C – FEBRUARY 1997 – NOVEMBER 1997
FUNCTION TABLES†
SINGLE-ENDED DRIVER
INPUT
(DA1)
OUTPUT
(DY1)
H
L
L
H
OPEN
L
DIFFERENTIAL DRIVER
INPUT ENABLE OUTPUT
(DA2) (DEN) (DY2) (DZ2)
H
L
H
L
L
L
L
H
OPEN
L
H
L
X
H
Z
Z
X
OPEN
Z
Z
SINGLED-ENDED RECEIVER
INPUT
ENABLE OUTPUT
(RA2, RA3) (REN) (RY2) (RY3)
H
H
H
L
L
H
L
H
OPEN
H
H
H
SHORT‡
H
?
?
X
L
Z
Z
X
OPEN
Z
Z
DIFFERENTIAL RECEIVER
INPUT
ENABLE
(RA1) (RB1) (REN)
OUTPUT
(RY1)
H
L
H
H
L
H
H
L
OPEN
H
H
SHORT‡
H
?
X
X
L
Z
X
X
OPEN
Z
† H = high level, L = low level, X = irrelevant, ? = indeterminate, Z = high impedance (off)
‡ –0.2 V < VID < 0.2 V
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)§
Positive supply voltage range, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 to 7 V
Negative supply voltage range, VEE (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 7 to 0.5 V
Receiver input voltage range (RA, RB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 15 V to 15 V
Receiver differential input voltage range, VID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 12 V to 12 V
Receiver output voltage range (RY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 5.5 V
Driver output voltage range (Power Off) (DY1, DY2, DZ2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 15 V to 15 V
Driver output voltage range (Power On) (DY1, DY2, DZ2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 11 V to 11 V
Driver input voltage range (DA, REN, DEN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC +0.4 V
Electrostatic Discharge (All pins) Human Body Model (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 kV
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
§ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to network ground terminal unless otherwise noted.
2. This rating is per MIL-PRF-38535, Method 3015.7.
2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265