English
Language : 

SN74BCT29843 Datasheet, PDF (2/5 Pages) Texas Instruments – 9-BIT BUS-INTERFACE D-TYPE LATCH WITH 3-STATE OUTPUTS
SN74BCT29843
9-BIT BUS-INTERFACE D-TYPE LATCH
WITH 3-STATE OUTPUTS
SCBS022C – FEBRUARY 1989 – REVISED NOVEMBER 1993
logic symbol†
logic diagram (positive logic)
1
OE
14
PRE
11
CLR 13
LE
2
1D
3
2D
4
3D
5
4D
6
5D
7
6D
8
7D
9
8D
10
9D
EN
S2
R
C1
1D
2
OE 1
PRE 14
CLR 11
23
1Q
22
2Q
21
3Q
20
4Q
19
5Q
18
6Q
17
7Q
16
8Q
15
9Q
LE 13
2
1D
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
S
C1
1D
R
To Eight Other Channels
23 1Q
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Voltage range applied to any output in the disabled or power-off state, VO . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Voltage range applied to any output in the high state, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30 mA
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. This is a stress rating only, and
functional operation of the device at these or any other conditions beyond those indicated in the “recommended operating conditions” section of
this specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
recommended operating conditions
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature
MIN NOM MAX UNIT
4.5
5 5.5 V
2
V
0.8 V
–18 mA
– 24 mA
48 mA
0
70 °C
2–2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265