SN74AUC08
QUADRUPLE 2-INPUT POSITIVE-AND GATE
SCES512A – NOVEMBER 2003 – REVISED MARCH 2005
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
www.ti.com
VCC
Supply voltage range
VI
Input voltage range(2)
VO
Voltage range applied to any output in the high-impedance or power-off state(2)
VO
Output voltage range(2)
IIK
Input clamp current
VI < 0
IOK
Output clamp current
VO < 0
IO
Continuous output current
Continuous current through VCC or GND
θJA
Package thermal impedance(3)
Tstg
Storage temperature range
MIN
MAX
–0.5
3.6
–0.5
3.6
–0.5
3.6
–0.5 VCC + 0.5
–50
–50
±20
±100
47
–65
150
UNIT
V
V
V
V
mA
mA
mA
mA
°C/W
°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-5.
Recommended Operating Conditions(1)
VCC
Supply voltage
VIH
High-level input voltage
VIL
Low-level input voltage
VI
Input voltage
VO
Output voltage
IOH
High-level output current
IOL
Low-level output current
∆t/∆v Input transition rise or fall rate
TA
Operating free-air temperature
VCC = 0.8 V
VCC = 1.1 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 0.8 V
VCC = 1.1 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 0.8 V
VCC = 1.1 V
VCC = 1.4 V
VCC = 1.65 V
VCC = 2.3 V
VCC = 0.8 V
VCC = 1.1 V
VCC = 1.4 V
VCC = 1.65 V
VCC = 2.3 V
VCC = 0.8 V to 1.65 V(2)
VCC = 1.65 V to 1.95 V(3)
VCC = 2.3 V to 2.7 V(3)
MIN
0.8
VCC
0.65 × VCC
1.7
0
0
–40
MAX
2.7
0
0.35 × VCC
0.7
3.6
VCC
–0.7
–3
–5
–8
–9
0.7
3
5
8
9
20
15
5
85
UNIT
V
V
V
V
V
mA
mA
ns/V
°C
(1) All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,