English
Language : 

SN54F374_08 Datasheet, PDF (2/17 Pages) Texas Instruments – OCTAL EDGE-TRIGGERED D-TYPE FLIP-FLOPS WITH 3-STATE OUTPUTS
SN54F374, SN74F374
OCTAL EDGEĆTRIGGERED DĆTYPE FLIPĆFLOPS
WITH 3ĆSTATE OUTPUTS
SDFS077A − D2932, MARCH 1987 − REVISED OCTOBER 1993
logic symbol†
logic diagram (positive logic)
1
OE
11
CLK
3
1D
4
2D
7
3D
8
4D
13
5D
14
6D
17
7D
18
8D
EN
C1
1D
2
1Q
5
2Q
6
3Q
9
4Q
12
5Q
15
6Q
16
7Q
19
8Q
OE 1
11
CLK
3
1D
C1
1D
2 1Q
To Seven Other Channels
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −1.2 V to 7 V
Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA to 5 mA
Voltage range applied to any output in the disabled or power-off state . . . . . . . . . . . . . . . . . . . −0.5 V to 5.5 V
Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC
Current into any output in the low state: SN54F374 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mA
SN74F374 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 mA
Operating free-air temperature range: SN54F374 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
SN74F374 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
recommended operating conditions
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature
SN54F374
MIN NOM MAX
4.5
5 5.5
2
0.8
− 18
−3
20
− 55
125
SN74F374
MIN NOM MAX
4.5
5 5.5
2
0.8
− 18
−3
24
0
70
UNIT
V
V
V
mA
mA
mA
°C
2−2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265