English
Language : 

RI-TRP-0106 Datasheet, PDF (2/4 Pages) Texas Instruments – MOUNT-ON-METAL TRANSPONDER Numbering According to EN14803 for Waste Management Applications
RI-TRP-0106
SCBS875A – NOVEMBER 2008 – REVISED NOVEMBER 2010
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
Operating Temperature
Storage Temperature
–25 to 70°C
–25 to 85°C
RI-TRP-0106
www.ti.com
OPERATING CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
RI-TRP-0106 (1)
Functionality
Read only
Memory (Bits)
64
Memory (Pages)
1
Operating Frequency
134.2 kHz
Modulation
FSK (frequency shift keying) 134.2 kHz / 123.2 kHz
Transmission Principle
HDX (half duplex)
Power Source
Typical Reading Range
Powered from the reader signal (batteryless)
≤120 cm(2)
Typical Reading Time
70 ms
Case Material
Polypropylene, black
Protection Class
IP 67
Mounting
With screws or rivets on aluminum, iron, or steel
EMC
Programmed code is not affected by normal electromagnetic interference or X-rays
Signal Penetration
Transponder can be read through almost all non-metallic material
Mechanical Shock
IEC 68-2-27, Test Ea; 200 g, half sine, 3 ms, 3 axes, 6 shocks per axis
Vibration
IEC 68-2-6, Test Fc; 20 g, 20 Hz to 500 Hz, 3 axes, 10 cycles per axis
Dimensions
102 mm ± 1 mm × 36 mm ± 1 mm × 16.5 mm ± 1 mm
Weight
43 g
(1) Number coding based on EN14803 standard
(2) Depending on RF regulation in country of use, the reader antenna configuration used, and the environmental conditions.
2
Submit Documentation Feedback
Copyright © 2008–2010, Texas Instruments Incorporated
Product Folder Link(s): RI-TRP-0106