English
Language : 

RI-I17-114A-S1 Datasheet, PDF (2/4 Pages) Texas Instruments – Tag-it™ HF-I PRO STANDARD TRANSPONDER INLAYS CD
RI-I17-114A-S1
SCBS830 – DECEMBER 2005
SPECIFICATIONS (1)
www.ti.com
Supported standard
Recommended operating frequency
Passive resonance frequency (at 25°C)
Typical required activation field strength to read (at 25°C)
Typical required activation field strength to write (at 25°C)
Factory programmed read-only number
Memory (user programmable)
Typical programming cycles (at 25°C)
Data retention time (at 55°C)
Simultaneous identification of tags
Antenna size
Foil width
Foil pitch
Base material
Operating temperature
Storage temperature (single inlay)
Storage temperature (on reel)
Delivery
Typical quantity of good units per reel
PART NUMBER
RI-I17-114A-S1
ISO/IEC 15693-2, -3; ISO/IEC 18000-3
13.56 MHz
13.80 MHz ± 400 kHz (includes frequency offset to compensate further
integration into paper or PVC lamination)
110 dBµA/m(2)
113 dBµA/m(2)
64 bits
256 bits organized in 8-bit × 32-bit blocks
100,000
>10 years
Up to 50 tags per second (reader/antenna dependent)
Outer diameter: ø 32.5 mm +0.1 mm/–0.2 mm (~1.28 in)
Inner diameter: min. ø 18 mm (~0.7 in)
48 mm ± 0.5 mm (1.89 in ± 0.02 in)
50.8 mm +0.1 mm/–0.4 mm (2 in)
Substrate: PET (polyethylenetherephtalate); Antenna: aluminum
–25°C to 70°C
–40°C to 85°C (warpage may occur at upper temperature range)
–40°C to 40°C
Single-row tape wound on cardboard reel with 500-mm diameter
Reel outer width: approximately 60 mm (~2.36 in)
Reel inner width: approximately 50 mm (~1.97 in)
Hub diameter: 76.2 mm (3 in)
5,000
(1) For highest possible read-out coverage, operate readers at a modulation depth of 20% or higher.
(2) After integration into paper
SUPPORTED COMMAND SET
REQUEST
REQUEST CODE
REQUEST MODE(1)
INVENTORY ADDRESSED NON-ADDRESSED AFI
ISO 15693 Mandatory and Optional Commands
Inventory
0x01
ü
–
–
ü
Stay Quiet
0x02
–
ü
–
–
Read_Single_Block
0x20
–
ü
ü
–
Write_Single_Block
0x21
–
ü
ü
–
Lock_Block
0x22
–
ü
ü
–
TI Custom Commands
Kill
0xA4
–
ü
–
–
WriteSingleBlockPwd
0xA5
–
ü
–
–
(1) ü = Implemented, – = Not applicable
OPT. FLAG
0/–
0/–
–/1
–/1
–/1
–/1
–/1
2
Submit Documentation Feedback