English
Language : 

OPA2180_13 Datasheet, PDF (2/27 Pages) Texas Instruments – 0.1-μV/°C Drift, Low-Noise, Rail-to-Rail Output, 36-V, Zero-Drift OPERATIONAL AMPLIFIERS
OPA2180
OPA4180
SBOS584C – NOVEMBER 2011 – REVISED DECEMBER 2012
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
DUAL
OPA2180
QUAD
OPA4180
PACKAGE INFORMATION(1)
PACKAGE-LEAD
PACKAGE
DESIGNATOR
SPECIFIED
TEMPERATURE RANGE
PACKAGE MARKING
SO-8
MSOP-8
D
DGK
–40°C to +105°C
–40°C to +105°C
2180
2180
SO-14
TSSOP-14
D
–40°C to +105°C
OPA4180
PW
–40°C to +105°C
OPA4180
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or visit the
device product folder at www.ti.com.
ABSOLUTE MAXIMUM RATINGS(1)
Supply voltage
Signal input terminals
Output short-circuit(2)
Voltage
Current
Operating temperature
Storage temperature
Junction temperature
ESD ratings
Human body model (HBM)
Charged device model (CDM)
OPA2180, OPA4180
±20, 40 (single supply)
(V–) – 0.5 to (V+) + 0.5
±10
Continuous
–55 to +125
–65 to +150
+150
1.5
1
UNIT
V
V
mA
°C
°C
°C
kV
kV
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only and functional operation of the device at these or any other conditions beyond
those specified is not implied.
(2) Short-circuit to ground, one amplifier per package.
2
Submit Documentation Feedback
Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Links: OPA2180 OPA4180