English
Language : 

MC33078-EP Datasheet, PDF (2/19 Pages) Texas Instruments – DUAL HIGH-SPEED LOW-NOISE OPERATIONAL AMPLIFIER
MC33078-EP
DUAL HIGH-SPEED LOW-NOISE OPERATIONAL AMPLIFIER
SLOS495 – OCTOBER 2006
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
www.ti.com
VCC+
VCC–
VCC– to VCC+
θJA
TJ
Tstg
Supply voltage(2)
Supply voltage(2)
Supply voltage
Input voltage, either input(2)(3)
Input current(4)
Duration of output short circuit(5)
Package thermal impedance(6)(7)
Operating virtual junction temperature
Storage temperature range(8)
MIN
MAX
18
–18
36
VCC– or VCC+
±10
Unlimited
97
150
–65
150
UNIT
V
V
V
V
mA
°C/W
°C
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC–.
(3) The magnitude of the input voltage must never exceed the magnitude of the supply voltage.
(4) Excessive input current will flow if a differential input voltage in excess of approximately 0.6 V is applied between the inputs, unless
some limiting resistance is used.
(5) The output may be shorted to ground or either power supply. Temperature and/or supply voltages must be limited to ensure the
maximum dissipation rating is not exceeded.
(6) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(7) The package thermal impedance is calculated in accordance with JESD 51-7.
(8) Long-term high-temperature storage and/or extended use at maximum recommended operating conditions may result in a reduction of
overall device life. See http://www.ti.com/ep_quality for additional information on enhanced plastic packaging.
Recommended Operating Conditions
VCC–
VCC+
TA
Supply voltage
Operating free-air temperature
MIN
MAX UNIT
–5
–18
V
5
18
–55
125 °C
2
Submit Documentation Feedback