English
Language : 

LT1054_06 Datasheet, PDF (2/27 Pages) Texas Instruments – SWITCHED-CAPACITOR VOLTAGE CONVERTERS WITH REGULATORS
LT1054
SWITCHEDĆCAPACITOR VOLTAGE CONVERTERS
WITH REGULATORS
SLVS033F − FEBRUARY 1990 − REVISED NOVEMBER 2004
functional block diagram
VREF
6
VCC
8
Ref
FB/SD 1
7
OSC
2.5 V
R
+
−
R
Q
OSC
Q
Drive
Drive
CAP +
CAP −
2
CIN†
4
Drive
† External capacitors
Pin numbers shown are for the P package.
Drive
3
GND
COUT†
5
VOUT
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 V
Input voltage range, VI: FB/SD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to VCC
OSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to Vref
Junction temperature, TJ (see Note 2): LT1054C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125°C
LT1054I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135°C
Package thermal impedance, θJA (see Notes 3 and 4): DW package . . . . . . . . . . . . . . . . . . . . . . . . . . 57°C/W
P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The absolute maximum supply-voltage rating of 16 V is for unregulated circuits. For regulation-mode circuits with VOUT ≤ 15 V, this
rating may be increased to 20 V.
2. The devices are functional up to the absolute maximum junction temperature.
3. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) − TA)/θJA. Operating at the absolute maximum TJ of 150°C can impact reliability.
4. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
VCC
TA
Supply voltage
Operating free-air temperature range
LT1054C
LT1054I
MIN MAX UNIT
3.5
15 V
0
70
°C
−40
85
2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265