English
Language : 

LP358 Datasheet, PDF (2/6 Pages) Texas Instruments – ULTRA-LOW-POWER DUAL OPERATIONAL AMPLIFIERS
LP358, LP2904
ULTRA-LOW-POWER DUAL OPERATIONAL AMPLIFIERS
SLOS475 – AUGUST 2005
SCHEMATIC (EACH AMPLIFIER)
www.ti.com
VCC
OUT
IN−
IN+
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
VCC
Supply voltage range(2)
VID
Differential input voltage(3)
VI
Input voltage (either input)
Duration of output short circuit (one amplifier) to ground at (or below) TA = 25°C, VCC ≤ 15 V(4)
θJA
Package thermal impedance(5)(6)
D package
DGK package
TJ
Operating virtual junction temperature
Tstg
Storage temperature range
MIN
–0.3
–65
MAX
±16 or 32
±32
32
Unlimited
97
172
150
150
UNIT
V
V
V
°C/W
°C
°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values (except differential voltages and VCC specified for the measurement of IOS) are with respect to the network GND.
(3) Differential voltages are at IN+, with respect to IN–.
(4) Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
(5) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
ESD Protection
Human-Body Model
TEST CONDITIONS
TYP
UNIT
±2
kV
2