absolute maximum ratings at 25°C free-air temperature (unless otherwise noted)†‡
Supply and output voltage range, VCC and VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 15 V
Reverse input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V
Emitter-base reverse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V
Peak input forward current (pulse duration = 1 ms, 50% duty cycle, see Note 1) . . . . . . . . . . . . . . . . . . 50 mA
Peak transient input forward current (pulse duration 1 µs, 300 Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A
Average forward input current(see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 mA
Peak output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 mA
Average output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 mA
Base current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 mA
Input power dissipation at (or below) 70°C free-air temperature (see Note 3) . . . . . . . . . . . . . . . . . . . . . 45 mW
Output power dissipation at (or below) 70°C free-air temperature (see Note 4) . . . . . . . . . . . . . . . . . . 100 mW
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 100°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
‡ JEDEC registered data for 6N135 and 6N136
NOTES: 1. Derate linearly above 70°C free-air temperature at the rate of 1.67 mA/°C.
2. Derate linearly above 70°C free-air temperature at the rate of 0.83 mA/°C.
3. Derate linearly above 70°C free-air temperature at the rate of 1.50 mW/°C.
4. Derate linearly above 70°C free-air temperature at the rate of 3.33 mW/°C.
2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265