CD54ACT05 Datasheet, PDF (2/8 Pages) Texas Instruments – HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
CD54ACT05, CD74ACT05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS311C – JANUARY 2001 – REVISED JANUARY 2007
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
www.ti.com
VCC Supply voltage range
IIK
Input clamp current(2)
IOK
Output clamp current(2)
IO
Continuous current
θJA
Package thermal impedance(3)
Tstg Storage temperature range
VI < 0 or VI > VCC
VO < 0
E package
M package
MIN MAX UNIT
–0.5
6V
±20 mA
–50 mA
±50 mA
80
°C/W
86
–65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output negative voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions(1)
VCC
VIH
VIL
VI
VO
IOL
∆t/∆v
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
Low-level output current
Input transition rise or fall rate
TA = 25°C
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 5.5
24
10
–40°C TO
85°C
MIN MAX
4.5
5.5
2
0.8
0
VCC
0
5.5
24
10
–55°C TO
125°C
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 5.5
24
10
UNIT
V
V
V
V
V
mA
ns/V
(1) All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VOL
II
ICC
∆ICC
Ci
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
VI = VCC– 2.1 V
IOL = 50 mA
IOL = 24 mA
IOL = 50 mA(1)
IOL = 75 mA(1)
IO = 0
VCC
4.5 V
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
4.5 V to 5.5 V
TA = 25°C
MIN MAX
0.1
0.36
±0.1
4
2.4
10
–40°C TO
85°C
MIN MAX
0.1
0.44
1.65
±1
40
2.8
10
–55°C TO
125°C
MIN MAX
0.1
0.5
1.65
UNIT
V
±1 µA
80 µA
3 mA
10 pF
(1) Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage
to minimize power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive
capability at 125°C.
2