English
Language : 

BQ24013 Datasheet, PDF (2/21 Pages) Texas Instruments – SINGLE-CHIP, LI-ION CHARGE MANAGEMENT IC FOR HANDHELD APPLICATIONS (bq TINY)
bq24010, bq24012, bq24013, bq24014
SLUS530F − SEPTEMBER 2002 − REVISED AUGUST 2005
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during
storage or handling to prevent electrostatic damage to the MOS gates.
ORDERING INFORMATION
TA
CHARGE
REGULATION
VOLTAGE (V)(1)
OPTIONAL
FUNCTIONS(1)
PART NUMBER(2)
MARKINGS
4.2
PG and TS
bq24010DRCR
AZN
4.2
PG and CE
bq24012DRCR
AZP
−40°C to 125°C
4.2
4.2
CE and TTE
CE and TS
bq24013DRCR
bq24014DRCR
bq24014DRCT
AZQ
AZR
(1) Contact Texas Instruments for other options.
(2) The DRC package is available only taped and reeled. Quantities are 3,000 devices per reel (e.g. bq24010DRCR) and 250 devices per mini-reel
(e.g. bq24014DRCT).
DISSIPATION RATINGS
PACKAGE
DRC(1)
θJA
47 °C/W
TA < 40°C
POWER RATING
1.5 W
DERATING FACTOR
ABOVE TA = 40°C
0.021 W/°C
(1) This data is based on using the JEDEC High-K board and the exposed die pad is connected to a copper pad on the board. This is connected to the
ground plane by a 2x3 via matrix.
ABSOLUTE MAXIMUM RATINGS(1)
UNIT
Supply voltage range, (VCC all with respect to VSS)
Input voltage range(2)
IN, STAT1, STAT2, TS, PG, CE, TTE
BAT, OUT, ISET
−0.3 to 18
−0.3 to VCC
−0.3 to 7
V
VDC
Voltage difference between VCC and IN inputs
VCC − VIN
Output sink/source current
STAT1, STAT2, PG
± 0.5
V
15
mA
Output current
IN, OUT
1.5
A
Operating free−air temperature range, TA
Junction temperature range, TJ
Storage temperature, Tstg
−40 to 125
°C
−65 to 150
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
300
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are DC and with respect to VSS.
RECOMMENDED OPERATING CONDITIONS(1)
Supply voltage(1), VCC
Input voltage(1), VIN
Operating junction temperature range, TJ
(1) Pins VCC and IN must be tied together.
MIN NOM MAX UNIT
3.0
16.5
V
3.0
16.5
−40
125 °C
2