English
Language : 

THS4140 Datasheet, PDF (19/24 Pages) Texas Instruments – HIGH SPEED FULLY DIFFERENTIAL I/O AMPLIFIERS
THS4140, THS4141
HIGHĆSPEED FULLY DIFFERENTIAL I/O AMPLIFIERS
SLOS320E − MAY 2000 − REVISED JANUARY 2004
PRINCIPLES OF OPERATION
power-down mode
The power-down mode is used when power saving is required. The power-down terminal (PD) found on the
THS414x is an active low terminal. If it is left as a no-connect terminal, the device will always stay on due to an
internal 50 kΩ resistor to VCC. The threshold voltage for this terminal is approximately 1.4 V above VCC−. This
means that if the PD terminal is 1.4 V above VCC −, the device is active. If the PD terminal is less than 1.4 V above
VCC −, the device is off. For example, if VCC − = −5 V, then the device is on when PD reaches 3.6 V, (-5 V + 1.4
V = −3.6 V). By the same calculation, the device is off below −3.6 V. It is recommended to pull the terminal to
VCC − in order to turn the device off. The following graph shows the simplified version of the power-down circuit.
While in the power-down state, the amplifier goes into a high-impedance state. The amplifier output impedance
is typically greater than 1 MΩ in the power-down state.
VCC
50 kΩ
To Internal Bias
Circuitry Control
PD
VCC−
Figure 33. Simplified Power-Down Circuit
Due to the similarity of the standard inverting amplifier configuration, the output impedance appears to be very
low while in the power-down state. This is because the feedback resistor (Rf) and the gain resistor (R(g)) are
still connected to the circuit. Therefore, a current path is allowed between the input of the amplifier and the output
of the amplifier. An example of the closed-loop output impedance is shown in Figure 34.
THS4141
OUTPUT IMPEDANCE (IN SHUTDOWN)
vs
FREQUENCY
2200
VCC = ±5 V,
VI = 0.8 VPP RMS
PD = VCC−
1200
200
10 k
100 k
1M
10 M
f − Frequency − Hz
Figure 34
100 M
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
19