English
Language : 

TLV2543IDB Datasheet, PDF (18/28 Pages) Texas Instruments – 12-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL AND 11 ANALOG INPUTS
TLV2543C, TLV2543I
12-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 ANALOG INPUTS
SLAS096C – MARCH 1995 – REVISED JUNE 2000
PARAMETER MEASUREMENT INFORMATION
CS
(see Note A)
I/O
CLOCK
1
2
3
4
Access Cycle B
5
6
7
8
15
16
1
ÎÎÎÎÎÎÎÎÎÎÎÎ Sample Cycle B
DATA
OUT
A15
A14 A13
A12 A11
A10 A9
A8
A1
A0
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎ DATA
ÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎ INPUT
MSB
Previous Conversion Data
LSB
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Hi-Z State
B15
ÎÎÎÎÎ
C7
EOC
Initialize
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
t(conv)
A/D Conversion
Interval
Initialize
Figure 14. Timing for 16-Clock Transfer Using CS With MSB First
CS
(see Note A)
I/O
CLOCK
1
2
3
4
Access Cycle B
5
6
7
8
15
16
Sample Cycle B
DATA
OUT
A15
A14 A13 A12 A11 A10 A9
A8
A1
A0
Previous Conversion Data
ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎ DATA
ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎ INPUT
MSB
B7
B6
B5
B4
B3
B2
B1
B0
LSB
MSB
LSB
1
Low Level
B15
ÎÎÎÎÎÎÎÎC7 ÎÎ
EOC
Initialize
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous
Conversion Value
t(conv)
A/D Conversion
Interval
Figure 15. Timing for 16-Clock Transfer Not Using CS With MSB First
NOTE A: To minimize errors caused by noise at CS, the internal circuitry waits for a setup time after CS↓ before responding to control input signals.
Therefore, no attempt should be made to clock in an address until the minimum CS setup time has elapsed.
18