English
Language : 

PTH08T240F_08 Datasheet, PDF (18/37 Pages) Texas Instruments – 10-A, 4.5-V to 14-V INPUT, NON-ISOLATED POWER MODULE FOR 3-GHz DSP SYSTEMS
PTH08T240F
SLTS277C – DECEMBER 2006 – REVISED DECEMBER 2008........................................................................................................................................ www.ti.com
PTH08T240F Type C Capacitors
8-V Input
10
9
8
7
6
5
4
5-V Input
10
9
8
7
6
5
4
3
3
2
2
1
1
C - Capacitance - mF
Figure 18. Capacitor Type C,
5000 < C(µF)×ESR(mΩ) ≤ 10,000
(e.g. OS-CON)
C - Capacitance - mF
Figure 19. Capacitor Type C,
5000 < C(µF)×ESR(mΩ) ≤ 10,000
(e.g. OS-CON)
Table 6. Type C TurboTrans CO Values and Required RTT Selection Table
Transient Voltage Deviation (mV)
8-V Input
5-V Input
25% load step
(2.5 A)
50% load step
(5 A)
75% load step
(7.5 A)
CO
Minimum
Required Output
Capacitance (µF)
RTT
Required
TurboTrans
Resistor (kΩ)
CO
Minimum
Required Output
Capacitance (µF)
RTT
Required
TurboTrans
Resistor (kΩ)
20
40
60
1000
open
1040
787
18
36
54
1000
open
1180
169
16
32
48
1100
340
1350
82.5
14
28
42
1300
97.6
1600
45.3
12
24
36
1600
45.3
1930
26.7
10
20
30
2050
22.6
2420
14.7
8
16
24
2750
10.5
3200
6.49
6
12
18
4050
2.49
4560
1.0
RTT Resistor Selection
The TurboTrans resistor value, RTT can be determined from the TurboTrans programming, see Equation 4 .
RTT
=
40 ´ éë1- (CO 5000)ùû
éë(CO 1000)- 1ùû
(kW)
(4)
Where CO is the total output capacitance in µF. CO values greater than or equal to 5000 µF require RTT to be a
short, 0 Ω. (RTT results in a negative value when CO > 5000 µF).
To ensure stability, the value of RTT must be calculated using the minimum required output capacitance
determined from the capacitor transient response charts above.
18
Submit Documentation Feedback
Copyright © 2006–2008, Texas Instruments Incorporated
Product Folder Link(s): PTH08T240F