English
Language : 

LT1007 Datasheet, PDF (18/24 Pages) Linear Technology – Low Noise, High Speed Precision Operational Amplifiers
LT1007, LT1007A, LT1037, LT1037A
LOW-NOISE, HIGH-SPEED, PRECISION OPERATIONAL AMPLIFIERS
SLOS017C – D3195, FEBRUARY 1989 – REVISED JANUARY 1993
APPLICATION INFORMATION
noise testing
Figure 39 shows a test circuit for 0.1-Hz to 10-Hz peak-to-peak noise measurement of the LT1007 and LT1037.
The frequency response of this noise tester indicates that eeethe 0.1 Hz corner is defined by only one zero.
Because the time limit acts as an additional zero to eliminate noise contributions from the frequency band below
0.1 Hz, the test time to measure 0.1-Hz to 10-Hz noise should not exceed 10 seconds.
0.1 Hz to 10 Hz p-p NOISE TESTER
FREQUENCY RESPONSE
100
90
80
70
60
50
40
30
0.01
0.1
1
10
100
Frequency – Hz
0.1 µF
10 Ω
100 kΩ
†
2 kΩ
Voltage Gain
= 50,000
+
4.7 µF
LT1001
–
100 kΩ
4.3 kΩ
2.2 µF
22 µF
Scope
x1
RIN = 1 MΩ
110 kΩ
24.3 kΩ
0.1 µF
† Device under test
NOTE: All capacitor values are for non-polarized capacitors only.
Figure 39. 0.1-Hz To 10-Hz Noise Test Circuit
18