SBVS245A – OCTOBER 2014 – REVISED MARCH 2015
Layout Guidelines (continued)
Estimating the junction temperature can be done by using the thermal metrics ΨJT and ΨJB, shown in the
Thermal Information. These metrics are a more accurate representation of the heat transfer characteristics of the
die and the package than RθJA. The junction temperature can be estimated with Equation 2.
YJT:
T
J
=
T
T
+
YJT
·
P
D
YJB:
T
J
=
T
B
+
YJB
·
P
D
where:
• PD is the power dissipation shown by Equation 1,
• TT is the temperature at the center-top of the IC package,
• TB is the PCB temperature measured 1 mm away from the IC package on the PCB surface.
(2)
NOTE
Both TT and TB can be measured on actual application boards using a thermo-gun (an
infrared thermometer).
For more information about measuring TT and TB, see the application note Using New Thermal Metrics
(SBVA025), available for download at www.ti.com.