English
Language : 

TIBPAL16L8-15C Datasheet, PDF (15/17 Pages) Texas Instruments – HIGH-PERFORMANCE IMPACT E PAL CIRCUITS
TIBPAL 16L8-15C, TIBPAL 16R4-15C, TIBPAL 16R6-15C, TIBPAL 16R8-15C
HIGH-PERFORMANCE IMPACT ™ PAL® CIRCUITS
SRPS019A – FEBRUARY 1984 – REVISED APRIL 2000
PARAMETER MEASUREMENT INFORMATION
7V
From Output
Under Test
CL
(see Note A)
S1
R1
Test
Point
R2
LOAD CIRCUIT FOR 3-STATE OUTPUTS
Timing
Input
1.3 V
tsu
Data
Input
1.3 V
th
1.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
3.5 V
0.3 V
3.5 V
0.3 V
High-Level
Pulse
Low-Level
Pulse
1.3 V
tw
1.3 V
1.3 V
1.3 V
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
0.3 V
3.5 V
0.3 V
Input
tpd
In-Phase
Output
tpd
Out-of-Phase
Output
(see Note D)
1.3 V
1.3 V
1.3 V
1.3 V
3.5 V
0.3 V
tpd
VOH
1.3 V
VOL
tpd
VOH
1.3 V
VOL
Output
Control
(low-level
enabling)
ten
Waveform 1
S1 Closed
(see Note B)
ten
Waveform 2
S1 Open
(see Note B)
1.3 V
1.3 V
tdis
1.3 V
tdis
1.3 V
3.5 V
0.3 V
≈3.5 V
VOL + 0.3 V
VOL
VOH
VOH – 0.3 V
≈0 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance and is 50 pF for tpd and ten, 5 pF for tdis.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform
2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf ≤ 2 ns, duty cycle = 50%
D. When measuring propagation delay times of 3-state outputs from low to high, switch S1 is closed.
When measuring propagation delay times of 3-state outputs from high to low, switch S1 is open.
E. Equivalent loads may be used for testing.
Figure 3. Load Circuit and Voltage Waveforms
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265