BQ27505-J2 Datasheet, PDF (14/42 Pages) Texas Instruments – System-Side Impedance Track™ Fuel Gauge
bq27505-J2
System-Side Impedance Track™ Fuel Gauge
SLUS924 – APRIL 2009
www.ti.com
4.1.1.1.20 IT_DISABLE: 0x0023
This command disables the fuel gauge the Impedance Track™ algorithm, clears the IT Enable to 0x00
and causes the [QEN] flags to be cleared in the CONTROL_STATUS register. This command is only
available when the fuel gauge is UNSEALED.
4.1.1.1.21 CAL_MODE: 0X0040
This command instructs the fuel gauge to enter calibration mode. This command is only available when
the fuel gauge is UNSEALED.
4.1.1.1.22 RESET: 0x0041
This command instructs the fuel gauge to perform a full reset. This command is only available when the
fuel gauge is UNSEALED.
4.1.1.2 AtRate( ): 0x02/0x03
The AtRate( ) read-/write-word function is the first half of a two-function command set used to set the
AtRate value used in calculations made by the AtRateTimeToEmpty( ) function. The AtRate( ) units are in
mA.
The AtRate( ) value is a signed integer, with negative values interpreted as a discharge current value. The
AtRateTimeToEmpty( ) function returns the predicted operating time at the AtRate value of discharge. The
default value for AtRate( ) is zero and forces AtRateTimeToEmpty( ) to return 65,535. Both the AtRate( )
and AtRateTimeToEmpty( ) commands must only be used in NORMAL mode.
4.1.1.3 AtRateTimeToEmpty( ): 0x04/0x05
This read-word function returns an unsigned integer value of the predicted remaining operating time if the
battery is discharged at the AtRate( ) value in minutes with a range of 0 to 65,534. A value of 65,535
indicates AtRate( ) = 0. The fuel gauge updates AtRateTimeToEmpty( ) within 1 s after the system sets the
AtRate( ) value. The fuel gauge automatically updates AtRateTimeToEmpty( ) based on the AtRate( )
value every 1 s. Both the AtRate( ) and AtRateTimeToEmpty( ) commands must only be used in NORMAL
mode.
4.1.1.4 Temperature( ): 0x06/0x07
This read-/write-word function returns an unsigned integer value of the temperature in units of 0.1 K
measured by the fuel gauge. Write temperature to the gauge when the [WRTEMP] is 1.
4.1.1.5 Voltage( ): 0x08/0x09
This read-word function returns an unsigned integer value of the measured cell-pack voltage in mV with a
range of 0 to 6000 mV.
14
GENERAL DESCRIPTION